Be careful when running a vehicle-body calibration through INSCALIBRATE RBV. The VEHICLEBODYROTATION standard deviations are used as initial condition standard deviations. If sigmas in VEHICLEBODYROTATION are set very confident (i.e: close to zero), then the calibration will end almost immediately.