OEMV-2 & OEMV-2G MTBF
The following analysis is based on an industrial operating profile with a 100% operational duty cycle. The MTBF hours are calendar hours. Failure rates presented apply to the OEMV-2G under normal operating conditions. The failure rate is the summation of individually calculated failure rates for each component considering part type, operational stress levels, and de-rating characteristics.
ENVIRONMENTAL CONDITIONS
Operating Temperature: -40ºC to +85ºC
Storage Temperature: -40ºC to +85ºC
Humidity: 95% Non-Condensing
External Ambient Temperature +25ºC
Operating Environment GF
MTBF (Calculated) 1,784,901 Hours
Unit Failure Rate at 12 Months: 0.49% Units per Year
External Ambient Temperature +85ºC
Operating Environment GF
MTBF (Calculated) 314,886 Hours
Unit Failure Rate at 12 Months: 2.74% Units per Year
External Ambient Temperature +25ºC
Operating Environment GM
MTBF (Calculated) 1,176,739 Hours
Unit Failure Rate at 12 Months: 0.74% Units per Year
External Ambient Temperature +85ºC
Operating Environment GM
MTBF (Calculated) 269,183 Hours
Unit Failure Rate at 12 Months: 3.20% Units per Year